Search results for "imaging [Stars]"
showing 10 items of 415 documents
Comparison of Split-Window and Single-Channel Methods for Land Surface Temperature Retrieval from MODIS and AATSR Data
2008
In this study, two different methods for retrieving the Land Surface Temperature (LST) from Terra/Moderate Resolution Imaging Spectroradiometer (MODIS) and Envisat/Advanced Along Track Scanning Radiometer (AATSR) data are compared against a database of ground measured LSTs. These are the split-window (SW) and the single-channel (SC) methods. The SW method expresses LST as a combination of the brightness temperatures in the 11 iquestm and 12 iquestm channels with coefficients that can have local or global validity, depending on the way they are obtained. SC methods are based on the atmospheric radiative transfer equation. To solve this equation, convenient atmospheric temperature and water v…
Liver-related and extrahepatic events in patients with non-alcoholic fatty liver disease: a retrospective competing risks analysis.
2022
Background & Aim: Non-alcoholic fatty liver disease (NAFLD), and especially fibrotic non-alcoholic steatohepatitis, is associated with high risks of liver-related events (LRE) and extrahepatic events (EHE). We evaluated the competitive risk occurrence of LRE and EHE in a large cohort of biopsy-proven NAFLD stratified according to baseline severity of fibrosis. Methods: Two thousand one hundred thirty-five patients with biopsy-proven NAFLD were enrolled. Observed cumulative incidence functions (CIFs) were used to evaluate the risk of LRE and EHE; cause-specific Cox model and predicted CIFs were fitted to identify predictors of LRE and EHE. A replication cohort of NAFLD patients with live…
Modic changes-Their associations with low back pain and activity limitation: A systematic literature review and meta-analysis.
2018
Background Previous systematic reviews have reported positive associations between Modic changes (MCs) and low back pain (LBP), but due to their narrow scope and new primary studies, there is a need for a comprehensive systematic review. Our objectives were to investigate if MCs are associated with non-specific LBP and/or activity limitation and if such associations are modified by other factors. Methods A protocol for this review was registered at PROSPERO prior to commencing the work (PROSPERO record: CRD42015017350). The MEDLINE, CINAHL and EMBASE databases were searched for relevant studies from first record to June 15th 2016. Prospective or retrospective cross-sectional cohort studies …
DEPFET Macropixel Detectors for MIXS: First Electrical Qualification Measurements
2010
The Mercury Imaging X-ray Spectrometer (MIXS) is one of the instruments on board the Mercury Planetary Orbiter of the fifth European Space Agency (ESA) cornerstone mission BepiColombo. This spectrometer comprises two instruments and allows imaging X-ray spectroscopy of the Mercurian surface. The focal plane arrays for the energy and spatial resolved detection of X-rays are based on depleted P-channel FET (DEPFET) macropixel detectors. We report on the first electrical qualification measurements of DEPFET macropixel flight hardware, which are done at room temperature. The measurement of the transistor properties of all DEPFET pixels allows the selection of 100% electrically defect-free devic…
Non invasive tools for the diagnosis of liver cirrhosis
2014
Liver cirrhosis (LC), the end stage of many forms of chronic hepatitis of different etiologies is a diffuse process characterized by fibrosis and the conversion of normal liver architecture into structurally abnormal nodules surrounded by annular fibrosis. This chronic progressive clinical condition, leads to liver cell failure and portal hypertension, which can favour the onset of hepatocellular carcinoma. Defining the phase of the natural history is crucial for therapeutic choice and prognosis. Liver biopsy is currently considered the best available standard of reference but it has some limits, so alternative tools have been developed to substitute liver biopsy when assessing liver fibros…
Techniques, Tricks, and Stratagems of Oral Cavity Computed Tomography and Magnetic Resonance Imaging
2022
The oral cavity constitutes a complex anatomical area that can be affected by many developmental, inflammatory, and tumoural diseases. MultiSlice Computed Tomography (MSCT) and Magnetic Resonance Imaging (MRI) currently represent the essential and complementary imaging techniques for detecting oral cavity abnormalities. Advanced MRI with diffusion-weighted imaging (DWI) and dynamic contrast-enhanced perfusion-weighted imaging (DCE-PWI) has recently increased the ability to characterise oral lesions and distinguish disease recurrences from post therapy changes. The analysis of the oral cavity area via imaging techniques is also complicated both by mutual close appositions of different mucosa…
Comparing airborne and satellite retrievals of cloud optical thickness and particle effective radius using a spectral radiance ratio technique: two c…
2018
Solar radiation reflected by cirrus and deep convective clouds (DCCs) was measured by the Spectral Modular Airborne Radiation Measurement System (SMART) installed on the German High Altitude and Long Range Research Aircraft (HALO) during the Mid-Latitude Cirrus (ML-CIRRUS) and the Aerosol, Cloud, Precipitation, and Radiation Interaction and Dynamic of Convective Clouds System – Cloud Processes of the Main Precipitation Systems in Brazil: A Contribution to Cloud Resolving Modelling and to the Global Precipitation Measurement (ACRIDICON-CHUVA) campaigns. On particular flights, HALO performed measurements closely collocated with overpasses of the Moderate Resolution Imaging Spectroradiometer (…
Very high spectral resolution imaging spectroscopy: The Fluorescence Explorer (FLEX) mission
2016
The Fluorescence Explorer (FLEX) mission has been recently selected as the 8th Earth Explorer by the European Space Agency (ESA). It will be the first mission specifically designed to measure from space vegetation fluorescence emission, by making use of very high spectral resolution imaging spectroscopy techniques. Vegetation fluorescence is the best proxy to actual vegetation photosynthesis which can be measurable from space, allowing an improved quantification of vegetation carbon assimilation and vegetation stress conditions, thus having key relevance for global mapping of ecosystems dynamics and aspects related with agricultural production and food security. The FLEX mission carries the…
Validation of two portable bioelectrical impedance analyses for the assessment of body composition in school age children
2017
Background Bioelectrical impedance analysis (BIA) is a convenient and child-friendly method for longitudinal analysis of changes in body composition. However, most validation studies of BIA have been performed on adult Caucasians. The present cross-sectional study investigated the validity of two portable BIA devices, the Inbody 230 (BIA8MF) and the Tanita BC-418 (BIA8SF), in healthy Taiwanese children. Methods Children aged 7–12 years (72 boys and 78 girls) were recruited. Body composition was measured by the BIA8SF and the BIA8MF. Dual X-ray absorptiometry (DXA) was used as the reference method. Results There were strong linear correlations in body composition measurements between the BIA…
Gamma-ray irradiation tests on CCD and CMOS sensors used in imaging techniques
2012
Technologically-enhanced electronic devices are used in various fields as space imaging or diagnostic techniques in medicine. The devices can be exposed to intense radiation fluxes over time which may impair the functioning of the same apparatus, in particular in space applications. In this paper we report the results of a gamma irradiation tests on imaging sensors simulating the space radiation over a long time period. Two types of sensors are taken into consideration: CCD (Charge-Coupled Device) sensors and CMOS based on technology MOS (Metal Oxide semiconductor) used for the realization of transistors widely used in consumer electronics. The devices are supplied by Techno System (Italy),…